Machine-generated summaryThe buyer, the Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases in Ohrid, North Macedonia, procured medical dispensable material for interventional cardiology, specifically coronary stents. The subject of the agreement consisted of 11 separate parts covering coronary stents made of chromium, cobalt or platinum alloys, with permanent, bioabsorbable or biodegradable polymers, coated with an immunosuppressant inhibiting the m-TOR, in various diameters such as 2.0-4.5mm and lengths such as 9-50mm. The estimated value was EUR 479,674. The procedure is closed for bids; the deadline for submitting bids passed on 2026-09-30.
Description
11 lots
- Lot 1
- A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR estimated €49,430 · 12 months
- Lot 2
- A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity estimated €25,609 · 12 months
- Lot 3
- A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR. Diameter 2.0-4.5mm, length 9-50mm. estimated €106,991 · 12 months
- Lot 4
- A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR estimated €99,186 · 12 months
- Lot 5
- A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR estimated €57,560 · 12 months
- Lot 6
- A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR estimated €20,487 · 12 months
- Lot 7
- A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, length from 8 to 48mm, compatible with 5F guiding catheter for all dimensions estimated €12,439 · 12 months
- Lot 8
- A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickn estimated €14,146 · 12 months
- How tenders are scored
- Price; Quality
Show 3 more lots
- Lot 9
- A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142 estimated €32,520 · 12 months
- Lot 10
- A coronary stent made of cobalt-chromium alloy, multi-link, featuring a Peak-to-Valley stent design for treatment of tapered (conically narrowed) coronary lesions with small and large diameters, coated with a permanent polymer and the cytostatic everolimus (DES). Strut thickness: 81 micrometers. Diameter range: 2 to 5 mm, length from 8 to 48 mm, and expandable up to 5.75 mm for diameters of 3.5 to estimated €14,878 · 12 months
- Lot 11
- A coronary cobalt-chromium stent with a permanent polymer, elastomer, featuring 4 markers, two positioned proximally and two distally, with a WZ stent design and a vessel wall imprint of 40 μm for the Z strut and 72 μm for the W strut with an exceptional radiopacity, with a metal spring tip at the catheter, enabling easier navigation through the blood vessels and improved visibility, coated with a estimated €18,536 · 12 months
As the official notice states them.
Official source
Source: TED - Tenders Electronic Daily (Publications Office of the EU)
Always verify details on the official notice.
Report an error in this notice
Last verified against TED - Tenders Electronic Daily (Publications Office of the EU) 14 hours ago
The buyer
Full buyer profilePublic Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid
- notices in the register
- 5
- award
- 1
- awarded in total
- €470,776
Recent awards
Market context
- open now in Medical equipment & pharmaceuticals
- 8,167
- median open notice
- €260,000
Similar tenders
Open now
4
days left
€187,000
est. value
Awarded before
Never miss a tender like this
39 new notices in Medical equipment & pharmaceuticals in North Macedonia in the last 7 days. Get an email when new ones appear. Free.
Set up my alertOr follow just its CPV code, Angiography supplies: an email when new tenders arrive under it, no account needed.