Vai al contenuto
Aperlena

TED - Tenders Electronic Daily (Publications Office of the EU) verificato 5 giorni fa Bando di gara

Macedonia del Nord - Forniture per angiografia - Acquisto di materiale medico monouso per la cardiologia interventistica - stent coronarici

Originale North Macedonia - Angiography supplies - Procurement of medical dispensable material for Interventional Cardiology - coronary stents.

Chiusa Macedonia del Nord Severna Makedonija Apparecchiature mediche e farmaceutici

Stazione appaltante Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

479.674 € valore stimato

Dati principali

Chiusa
12:00 (UTC+2)
Procedura
Procedura aperta
  1. Pubblicata
  2. Scadenza aperta 29 giorni
  3. Aggiudicata in attesa
Vedi l'avviso ufficiale Segui questa gara

Le offerte sono chiuse. Un'aggiudicazione o una rettifica su questo avviso: un'email quando il registro lo vede. Accedi

Sintesi

Sintesi generata automaticamente

L'acquirente è stato l'istituto pubblico sanitario, ospedale specializzato per la prevenzione, la cura e la riabilitazione delle malattie cardiovascolari di Ohrid, in Macedonia del Nord. Ha acquistato materiale medico monouso per la cardiologia interventistica, in particolare stent coronarici. L'oggetto dell'accordo comprendeva 11 parti distinte, coprenti stent in leghe di cromo, cobalto o platino, con polimeri permanenti, bioassorbibili o biodegradabili, rivestiti con un immunosoppressore che inibisce il m-TOR, con diametri come 2,0-4,5mm e lunghezze come 9-50mm. Il valore stimato era di EUR 479 674. La procedura è chiusa alle offerte; il termine per la presentazione delle offerte è scaduto il 2026-09-30.

Descrizione

The subject of the agreement consists of 11 separate parts, including: A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity; A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR. Diameter 2.0-4.5mm, length 9-50mm.; A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, length from 8 to 48mm, compatible with 5F guiding catheter for all dimensions; A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, - maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.; A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142cm+/-3cm, - shaft diameter: proximal 2.0F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, -maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.; A coronary stent made of cobalt-chromium alloy, multi-link, featuring a Peak-to-Valley stent design for treatment of tapered (conically narrowed) coronary lesions with small and large diameters, coated with a permanent polymer and the cytostatic everolimus (DES). Strut thickness: 81 micrometers. Diameter range: 2 to 5 mm, length from 8 to 48 mm, and expandable up to 5.75 mm for diameters of 3.5 to 5.0 mm, and up to 3.75 mm for diameters of 2.0 to 3.25 mm, without shortening; A coronary cobalt-chromium stent with a permanent polymer, elastomer, featuring 4 markers, two positioned proximally and two distally, with a WZ stent design and a vessel wall imprint of 40 μm for the Z strut and 72 μm for the W strut with an exceptional radiopacity, with a metal spring tip at the catheter, enabling easier navigation through the blood vessels and improved visibility, coated with a drug from the LIMUS family, with diameters ranging from 2.25 to 4.00 mm and length from 8 to 44 mm, or equivalent

Fonte ufficiale

Fonte: TED - Tenders Electronic Daily (Publications Office of the EU)

Verifica sempre i dettagli nell'avviso ufficiale.

Segnala un errore in questo bando

Ultima verifica su TED - Tenders Electronic Daily (Publications Office of the EU) 5 giorni fa

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

Macedonia del Nord

avvisi nel registro
5
aggiudicazione
1
aggiudicati in totale
470.776 €

Un punto per aggiudicazione, nel giorno della firma, grande quanto il suo importo. Un anello è un'aggiudicazione senza importo pubblicato.

Aggiudicazioni recenti

Contesto di mercato

aperti ora in Apparecchiature mediche e farmaceutici
11.278
avviso aperto mediano
136.030 €

Gare simili

Aperte ora

Già aggiudicate

Non perderti nessuna gara come questa

35 nuovi avvisi per Apparecchiature mediche e farmaceutici in Macedonia del Nord negli ultimi 7 giorni. Ricevi un'email quando escono nuovi avvisi. Gratis.

Crea il mio avviso

Oppure segui solo il suo codice CPV, Presidi per angiografia: una email quando arrivano nuove gare sotto di esso, senza account.

Scorciatoie da tastiera

Scorri un elenco senza toccare il mouse. Le scorciatoie restano inattive mentre scrivi in un campo.

j
Risultato successivo
k
Risultato precedente
Invio
Apri il risultato
n
Pagina successiva
p
Pagina precedente
c
Confronta questo risultato
s
Aggiungi questo risultato alla shortlist
o
Apri il risultato in una nuova scheda
x
Metti da parte questo risultato
/
Cerca da qualsiasi pagina
Ctrl K
Cerca da qualsiasi pagina
?
Mostra queste scorciatoie
Esc
Chiudi

Indice

Chiudi
Accedi

Lingua