Saltar al contenido
Aperlena

TED - Tenders Electronic Daily (Publications Office of the EU) verificado hace 5 días Anuncio de licitación

Macedonia del Norte - Suministros de angiografía - Adquisición de material médico desechable para cardiología intervencionista - stents coronarios

Original North Macedonia - Angiography supplies - Procurement of medical dispensable material for Interventional Cardiology - coronary stents.

Cerrada Macedonia del Norte Severna Makedonija Equipos médicos y productos farmacéuticos

Órgano de contratación Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

479.674 € valor estimado

Datos clave

Cerrada
12:00 (UTC+2)
Procedimiento
Procedimiento abierto
  1. Publicada
  2. Fecha límite abierta 29 días
  3. Adjudicada pendiente
Ver el anuncio oficial Vigilar esta licitación

El plazo de ofertas ha cerrado. Una adjudicación o una corrección de este anuncio: un email cuando el registro lo ve. Iniciar sesión

Resumen

Resumen generado automáticamente

El comprador fue la institución pública de salud, hospital especializado para la prevención, el tratamiento y la rehabilitación de enfermedades cardiovasculares de Ohrid, en Macedonia del Norte. Se adquirió material médico desechable para cardiología intervencionista, concretamente stents coronarios. El objeto del contrato constaba de 11 partes separadas, que abarcaban stents de aleaciones de cromo, cobalto o platino, con polímeros permanentes, bioabsorbibles o biodegradables, recubiertos con un inmunosupresor que inhibe el m-TOR, con diámetros como 2,0-4,5mm y longitudes como 9-50mm. El valor estimado era de EUR 479 674. El procedimiento está cerrado a ofertas; el plazo para presentarlas finalizó el 2026-09-30.

Descripción

The subject of the agreement consists of 11 separate parts, including: A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity; A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR. Diameter 2.0-4.5mm, length 9-50mm.; A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, length from 8 to 48mm, compatible with 5F guiding catheter for all dimensions; A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, - maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.; A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142cm+/-3cm, - shaft diameter: proximal 2.0F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, -maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.; A coronary stent made of cobalt-chromium alloy, multi-link, featuring a Peak-to-Valley stent design for treatment of tapered (conically narrowed) coronary lesions with small and large diameters, coated with a permanent polymer and the cytostatic everolimus (DES). Strut thickness: 81 micrometers. Diameter range: 2 to 5 mm, length from 8 to 48 mm, and expandable up to 5.75 mm for diameters of 3.5 to 5.0 mm, and up to 3.75 mm for diameters of 2.0 to 3.25 mm, without shortening; A coronary cobalt-chromium stent with a permanent polymer, elastomer, featuring 4 markers, two positioned proximally and two distally, with a WZ stent design and a vessel wall imprint of 40 μm for the Z strut and 72 μm for the W strut with an exceptional radiopacity, with a metal spring tip at the catheter, enabling easier navigation through the blood vessels and improved visibility, coated with a drug from the LIMUS family, with diameters ranging from 2.25 to 4.00 mm and length from 8 to 44 mm, or equivalent

Fuente oficial

Fuente: TED - Tenders Electronic Daily (Publications Office of the EU)

Verifica siempre los detalles en el anuncio oficial.

Avisar de un error en este anuncio

Última verificación con TED - Tenders Electronic Daily (Publications Office of the EU) hace 5 días

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

Macedonia del Norte

anuncios en el registro
5
adjudicación
1
adjudicados en total
470.776 €

Un punto por adjudicación, en el día en que se firmó, con el tamaño de su importe. Un anillo es una adjudicación sin importe publicado.

Adjudicaciones recientes

Contexto de mercado

abiertos ahora en Equipos médicos y productos farmacéuticos
11.256
anuncio abierto mediano
135.785 €

Licitaciones similares

Abiertas ahora

Adjudicadas antes

No te pierdas ninguna licitación como esta

37 anuncios nuevos de Equipos médicos y productos farmacéuticos en Macedonia del Norte en los últimos 7 días. Recibe un email cuando aparezcan anuncios nuevos. Gratis.

Crear mi alerta

O sigue solo su código CPV, Material para angiografías: un correo cuando lleguen licitaciones nuevas bajo él, sin cuenta.

Atajos de teclado

Recorre una lista sin tocar el ratón. Los atajos no actúan mientras escribes en un campo.

j
Resultado siguiente
k
Resultado anterior
Intro
Abrir el resultado
n
Página siguiente
p
Página anterior
c
Comparar este resultado
s
Añadir este resultado a la lista corta
o
Abrir el resultado en una pestaña nueva
x
Apartar este resultado
/
Buscar desde cualquier página
Ctrl K
Buscar desde cualquier página
?
Mostrar estos atajos
Esc
Cerrar

Índice

Cerrar
Iniciar sesión

Idioma