Vai al contenuto
Aperlena

TED - Tenders Electronic Daily (Publications Office of the EU) verificato 4 giorni fa Avviso di aggiudicazione

North Macedonia - Angiography supplies - Procurement of medical dispensable material for Interventional Cardiology - coronary stents.

Aggiudicata Macedonia del Nord Severna Makedonija Apparecchiature mediche e farmaceutici

Stazione appaltante Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

470.776 € importo aggiudicato

Dati principali

Aggiudicata
Importo stimato
479.674 €
Procedura
Procedura aperta
  1. Aggiudicata
  2. Pubblicata
Vedi l'avviso ufficiale Segui questa gara

Le offerte sono chiuse. Un'aggiudicazione o una rettifica su questo avviso: un'email quando il registro lo vede. Accedi

Aggiudicato a

АЛКАЛОИД КОНС ДООЕЛ; БИО МЕДИКА ДООЕЛ Скопје; ВЕНОФИТ ДООЕЛ Скопје; AD Д-Р ПАНОВСКИ; ПРОМЕДИКА ДОО Скопје; ФАРМА ТРЕЈД ДООЕЛ

Importo aggiudicato
470.776 €
Data di aggiudicazione
Offerte ricevute
9 su 9 lotti
Storico con questo committente
1 primo contratto da questo committente nel registro

Descrizione

The subject of the agreement consists of 9 separate parts A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity; A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, long from 8 to 48mm, compatible with 5F guiding catheter for all dimensions; A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, - maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.; A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142cm+/-3cm, - shaft diameter: proximal 2.0F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, -maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.

Fonte ufficiale

Fonte: TED - Tenders Electronic Daily (Publications Office of the EU)

Verifica sempre i dettagli nell'avviso ufficiale.

Segnala un errore in questo bando

Ultima verifica su TED - Tenders Electronic Daily (Publications Office of the EU) 4 giorni fa

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

Macedonia del Nord

avvisi nel registro
5
aggiudicazione
1
aggiudicati in totale
470.776 €

Un punto per aggiudicazione, nel giorno della firma, grande quanto il suo importo. Un anello è un'aggiudicazione senza importo pubblicato.

Contesto di mercato

aperti ora in Apparecchiature mediche e farmaceutici
11.274
avviso aperto mediano
140.000 €

Fatti di procedura

  • Ciascuno dei suoi 9 lotti ha ricevuto una sola offerta (procedura aperta).

Fatti che ricercatori e giornalisti seguono nei registri pubblici. Nessuno è prova di un illecito: ognuno ha spiegazioni ordinarie, come un mercato specializzato, un'esigenza urgente o pochi fornitori qualificati.

Gare simili

Aperte ora

Già aggiudicate

Non perderti nessuna gara come questa

31 nuovi avvisi per Apparecchiature mediche e farmaceutici in Macedonia del Nord negli ultimi 7 giorni. Ricevi un'email quando escono nuovi avvisi. Gratis.

Crea il mio avviso

Scorciatoie da tastiera

Scorri un elenco senza toccare il mouse. Le scorciatoie restano inattive mentre scrivi in un campo.

j
Risultato successivo
k
Risultato precedente
Invio
Apri il risultato
n
Pagina successiva
p
Pagina precedente
c
Confronta questo risultato
s
Aggiungi questo risultato alla shortlist
o
Apri il risultato in una nuova scheda
x
Metti da parte questo risultato
/
Cerca da qualsiasi pagina
Ctrl K
Cerca da qualsiasi pagina
?
Mostra queste scorciatoie
Esc
Chiudi

Indice

Chiudi
Accedi

Lingua