Aller au contenu
Aperlena

TED - Tenders Electronic Daily (Publications Office of the EU) vérifié il y a 6 jours Avis de marché

North Macedonia - Angiography supplies - Procurement of medical dispensable material for Interventional Cardiology - coronary stents.

Clôturé Macédoine du Nord Severna Makedonija Équipements médicaux & produits pharmaceutiques

Acheteur public Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

479 674 € valeur estimée

Informations clés

Clôturé
12:00 (UTC+2)
Procédure
Procédure ouverte
  1. Publié
  2. Date limite ouvert 26 jours
  3. Attribué en attente
Consulter l'avis officiel Suivre ce marché

Les offres sont closes. Une attribution ou un rectificatif sur cet avis : un e-mail quand le registre le voit. Se connecter

Description

The subject of the agreement consists of 9 separate parts A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity; A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, long from 8 to 48mm, compatible with 5F guiding catheter for all dimensions; A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, - maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.; A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142cm+/-3cm, - shaft diameter: proximal 2.0F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, -maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.

Source officielle

Source : TED - Tenders Electronic Daily (Publications Office of the EU)

Vérifiez toujours les détails dans l'avis officiel.

Signaler une erreur dans cet avis

Dernière vérification auprès de TED - Tenders Electronic Daily (Publications Office of the EU) il y a 6 jours

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

Macédoine du Nord

avis dans le registre
5
attribution
1
attribués au total
470 776 €

Un point par attribution, au jour de sa signature, à la taille de son montant. Un anneau est une attribution sans montant publié.

Attributions récentes

Contexte de marché

ouverts en ce moment, Équipements médicaux & produits pharmaceutiques
11 274
avis ouvert médian
140 000 €

Marchés similaires

Ouverts en ce moment

Déjà attribués

Ne manquez plus aucun marché comme celui-ci

35 nouveaux avis pour Équipements médicaux & produits pharmaceutiques en Macédoine du Nord au cours des 7 derniers jours. Recevez un e-mail quand de nouveaux avis paraissent. Gratuit.

Créer mon alerte

Raccourcis clavier

Parcourir une liste sans toucher la souris. Les raccourcis restent inactifs pendant la saisie dans un champ.

j
Résultat suivant
k
Résultat précédent
Entrée
Ouvrir le résultat
n
Page suivante
p
Page précédente
c
Comparer ce résultat
s
Ajouter ce résultat à la présélection
o
Ouvrir le résultat dans un nouvel onglet
x
Écarter ce résultat
/
Rechercher depuis n’importe quelle page
Ctrl K
Rechercher depuis n’importe quelle page
?
Afficher ces raccourcis
Échap
Fermer

Sommaire

Fermer
Se connecter

Langue