Zum Inhalt springen
Aperlena

TED - Tenders Electronic Daily (Publications Office of the EU) geprüft vor 6 Tagen Auftragsbekanntmachung

North Macedonia - Angiography supplies - Procurement of medical dispensable material for Interventional Cardiology - coronary stents.

Geschlossen Nordmazedonien Severna Makedonija Medizintechnik & Arzneimittel

Auftraggeber Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

479.674 € geschätzter Wert

Eckdaten

Geschlossen
12:00 (UTC+2)
Verfahren
Offenes Verfahren
  1. Veröffentlicht
  2. Frist 26 Tage offen
  3. Vergeben ausstehend
Zur amtlichen Bekanntmachung Ausschreibung beobachten

Die Angebotsfrist ist vorbei. Ein Zuschlag oder eine Berichtigung zu dieser Bekanntmachung: eine E-Mail, wenn das Register es sieht. Anmelden

Beschreibung

The subject of the agreement consists of 9 separate parts A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity; A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, long from 8 to 48mm, compatible with 5F guiding catheter for all dimensions; A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, - maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.; A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142cm+/-3cm, - shaft diameter: proximal 2.0F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, -maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.

Amtliche Quelle

Quelle: TED - Tenders Electronic Daily (Publications Office of the EU)

Prüfen Sie alle Angaben stets in der amtlichen Bekanntmachung.

Einen Fehler in dieser Bekanntmachung melden

Zuletzt mit TED - Tenders Electronic Daily (Publications Office of the EU) abgeglichen vor 6 Tagen

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

Nordmazedonien

Bekanntmachungen im Register
5
Zuschlag
1
insgesamt vergeben
470.776 €

Ein Punkt je Zuschlag, am Tag der Unterzeichnung, in der Größe seines Werts. Ein Ring ist ein Zuschlag ohne veröffentlichten Wert.

Jüngste Vergaben

Marktkontext

jetzt offen im Bereich Medizintechnik & Arzneimittel
11.274
Median der offenen Bekanntmachungen
140.000 €

Ähnliche Ausschreibungen

Jetzt offen

Früher vergeben

Verpassen Sie keine Ausschreibung wie diese

35 neue Bekanntmachungen für Medizintechnik & Arzneimittel in Nordmazedonien in den letzten 7 Tagen. Erhalten Sie eine E-Mail, wenn neue erscheinen. Kostenlos.

Benachrichtigung einrichten

Tastaturkürzel

Eine Liste lesen, ohne zur Maus zu greifen. In einem Eingabefeld bleiben die Kürzel stumm.

j
Nächstes Ergebnis
k
Vorheriges Ergebnis
Enter
Ergebnis öffnen
n
Nächste Seite
p
Vorherige Seite
c
Dieses Ergebnis vergleichen
s
Dieses Ergebnis auf die Merkliste setzen
o
Ergebnis in neuem Tab öffnen
x
Dieses Ergebnis beiseitelegen
/
Von jeder Seite aus suchen
Strg K
Von jeder Seite aus suchen
?
Diese Kürzel anzeigen
Esc
Schließen

Verzeichnis

Schließen
Anmelden

Sprache