Aller au contenu
Aperlena

TED - Tenders Electronic Daily (Publications Office of the EU) vérifié il y a 4 jours Avis d'attribution

North Macedonia - Angiography supplies - Procurement of medical dispensable material for Interventional Cardiology - coronary stents.

Attribué Macédoine du Nord Severna Makedonija Équipements médicaux & produits pharmaceutiques

Acheteur public Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

470 776 € montant attribué

Informations clés

Attribué
Montant estimé
479 674 €
Procédure
Procédure ouverte
  1. Attribué
  2. Publié
Consulter l'avis officiel Suivre ce marché

Les offres sont closes. Une attribution ou un rectificatif sur cet avis : un e-mail quand le registre le voit. Se connecter

Description

The subject of the agreement consists of 9 separate parts A coronary stent made of a chromium alloy (cobalt or platinum) with a continuous sinusoidal configuration and a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium alloy (cobalt or platinum) with a bioabsorbable polymer and hybrid coating with an active component of an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR and a passive component that lowers the thrombogenicity; A coronary stent made of a chromium and cobalt alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and cobalt alloy with a hybrid cell design and a low stent crossing profile ≤ 0.041” (it refers to a stent with a diameter of up to 3mm), with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of multiple cobalt alloys (chromium or nickel) designed for large post-dilatation expansions ≥ 5.5mm in large blood vessels, with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with a permanent polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR; A coronary stent made of a chromium and platinum alloy with an abluminal biodegradable polymer, coated with an immunosuppressant that stops the cell cycle progression by inhibiting the m-TOR, with a diameter from 2.25 to 5mm, long from 8 to 48mm, compatible with 5F guiding catheter for all dimensions; A coronary stent made of a chromium and cobalt alloy, with a polymer and carrier free technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine shall be 30 days or less, - effective length of the shaft 142cm+/3cm, - shaft diameter: proximal 2.1F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, - maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.; A coronary stent made of a chromium and cobalt alloy, with a biodegradable polymer (PLA) technology, coated with an immunosuppressant on the abluminal surface that stops the cell cycle progression by inhibiting the m-TOR. - time of delivery of the medicine and polymer absorption shall be synchronized, for 9 months or less, -Lesion entry profile: 0.017“ or less, - effective length of the shaft 142cm+/-3cm, - shaft diameter: proximal 2.0F or less, distal 2.6F or less - struts thickness: 85 micrometers or less, for a stent with a diameter of up to 3.0mm, - stent length: 9-36mm or longer, - stent diameter: 2.25-4.0mm or more, -maximum expansion of the stent diameter 5.95mm for stents with a diameter of 3.5mm and 4mm.

Source officielle

Source : TED - Tenders Electronic Daily (Publications Office of the EU)

Vérifiez toujours les détails dans l'avis officiel.

Signaler une erreur dans cet avis

Dernière vérification auprès de TED - Tenders Electronic Daily (Publications Office of the EU) il y a 4 jours

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

Macédoine du Nord

Contexte de marché

ouverts en ce moment, Équipements médicaux & produits pharmaceutiques
11 293
avis ouvert médian
136 622 €

Faits de procédure

  • Chacun de ses 9 lots a reçu une seule offre (procédure ouverte).

Des faits que chercheurs et journalistes suivent dans les registres publics. Aucun n'est la preuve d'une irrégularité : chacun a des explications ordinaires, comme un marché spécialisé, un besoin urgent ou peu de fournisseurs qualifiés.

Marchés similaires

Ouverts en ce moment

Déjà attribués

Ne manquez plus aucun marché comme celui-ci

35 nouveaux avis pour Équipements médicaux & produits pharmaceutiques en Macédoine du Nord au cours des 7 derniers jours. Recevez un e-mail quand de nouveaux avis paraissent. Gratuit.

Créer mon alerte

Raccourcis clavier

Parcourir une liste sans toucher la souris. Les raccourcis restent inactifs pendant la saisie dans un champ.

j
Résultat suivant
k
Résultat précédent
Entrée
Ouvrir le résultat
n
Page suivante
p
Page précédente
c
Comparer ce résultat
s
Ajouter ce résultat à la présélection
o
Ouvrir le résultat dans un nouvel onglet
x
Écarter ce résultat
/
Rechercher depuis n’importe quelle page
Ctrl K
Rechercher depuis n’importe quelle page
?
Afficher ces raccourcis
Échap
Fermer

Sommaire

Fermer
Se connecter

Langue