Aller au contenu
Aperlena

TED - Tenders Electronic Daily (Publications Office of the EU) vérifié il y a 3 jours Avis de marché

North Macedonia - Angiography supplies - Procurement of goods - dispensable material for endovascular procedures on the peripheral vascular system.

Clôturé Macédoine du Nord Severna Makedonija Équipements médicaux & produits pharmaceutiques

Acheteur public Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

341 463 € valeur estimée

Informations clés

Clôturé
12:00 (UTC+1)
Procédure
Procédure ouverte
  1. Publié
  2. Date limite ouvert 29 jours
  3. Attribué en attente
Consulter l'avis officiel Suivre ce marché

Les offres sont closes. Une attribution ou un rectificatif sur cet avis : un e-mail quand le registre le voit. Se connecter

Description

The subject of the agreement consists of 41 separate parts -Z-Cell design with radiopaque markers on both ends of the stent - an ergonomic handle for positioning (single-hand stent deployment) - an internal port for rinsing - compatible with 0.035” wire and 6F introducer - stent length: 40-120mm - diameter: 5-8mm - catheter length: 80cm or 125cm; - the system shall be placed on a triaxial catheter for precise placement, with a working length of 130 cm - compatible with 0.035” (0.89 mm) guide wire and introducers with a maximum of 6F for all dimensions - stent diameters of 6mm and 7 mm - stent length: from 40 - 120 mm - the drug dose should not be more than 0.200 µg/mm² - the drug shall be released from the device surface in order to have a local effect on the tissue, and to reach a therapeutic concentration in a period of at least 12 months; - Rx system - compatible with 5F introducer sheath - diameter: 5-10mm - stent length: 16-40 mm - a possibility for reposition during expansion of up to 50%; - the stent diameter shall adapt to the tapered shape of the carotid artery - there shall be a possibility of repositioning the wire up to 50% of the initial placement, allowing precise stent placement - to have a closed design that provides an increased protection for covering the lesion, plaque control, angiographic results and embolic protection during device removal - available in diameters from 5 mm to 9 mm, length from 30 mm to 50 mm - catheter length: 135 cm; - OTW technique - biomimetric - diameter: 4.5-6.5 mm - stent length: 20-200 mm - 6F compatible - catheter length: 120 cm maximum; - compatible with 6F introducer sheath and 0.018” wire - Rx system - diameter: 5-8mm - stent length from 40 to 155 mm; - Straight и tapered configuration - with a so-called closed cell design - RX technique - diameter 6-10mm and length 20-40mm - compatible with 6F guiding introducer; - stainless steel - with a so-called open cell design - radiopaque markers on both ends of the stent and balloon catheter - the stent shall be placed on a balloon catheter with a length of 80-135cm - the stent shall be based on the OTW system, compatible with a guide wire 0.035” - stent diameter: 5-10mm - compatible with 6-7F introducers - stent length: from 12mm or less, to 57 mm or more; -OTW system - struts thickness: 110μm (5-7mm) - with PROBIO coating (amоrphous silicon carbidе) - compatible with a 0.035" guide wire - on a carrier available in lengths of 90,135 and 170cm - stent length: 18 - 78mm - diameter: 5-10mm; - OTW system - equipped with a mechanism for a precise placement of the stent - compatible with a 4F introducer - with amprphous silicon-carbid coating - with markers - compatible with a 0.018“ guide wire - length: 20 mm or less, to 200 mm or more -diameter: 4 mm or less to 7mm or more - struts thickness: 140 μm or less - carrier length: 80cm (+/-10cm) to 130cm (+/-5cm); - with a so-called open cell design - equipped with a single-hand ergonomic system for placement with a triaxial design with a mechanism for accurate stent positioning -OTW technique - compatible with 5F introducer and 0.035" guide wire - catheter length: 80cm-150cm - stent diameter: 5-8mm - stent length: 20-150mm and more; - the integrated balloon catheter shall have radially arranged spikes that create channels to improve vascular compliance, reduce vascular recoil, and enhance drug absorption (for controlled penetration and lesion preparation) - device diameter: 3.0 mm (for vessels 2.5 - 3.5 mm) and 4.0 mm (for vessels 3.5 - 4.5 mm) - effective catheter length of 135 cm and a hydrophilic coating on the distal segment; - a stent made of stainless steel - open cell design - fully encapsulated in a single PTFE layer with controlled porosity of 55 μm - minimum diameter range: from 5 to 10mm - minimum length range: from 16 to 59mm - compatible with 6-7 F introducer and 0.035” guide wire -catheter length: 80 and 120 cm; -OTW technique - catheter length: 50cm-150cm+/-5% - balloon length from 2cm to 12cm, or longer - inflatable balloon with a diameter from 1.5mm to 3mm, or larger - burst pressure:16atm+/-5% - accepts 0.014“ guide wire - compatible with “sheath“ of 3F; - shall be indicated for carotid, coronary, and peripheral interventional procedures - the system shall allow independent movement of the wire and enable longitudinal and rotational movement of the filter - to include an option to fracture the wire and use the remaining portion as the primary guide wire through the catheter based on the RX technique - filter dimension: 3-7mm - wire length: 320/190cm (+/-5cm), compatible with a guide wire with a diameter of 0.014-0.018" and 5F introducer; - compatible with 6F catheter, length 190 cm and 300 cm - MR 0.014 system - profile: 3.2 F (1.1mm) - nitinol filter loop; Consists of: 1. Multifunctional balloon catheter, OTW system 0.014 and 0.018, various lengths 86-93-141-142cm and 2-7mm diameter 2. PTA balloon catheter for support, available in 4F и 6F и 2-7mm diameter Used for antegrade (4F/0.014) and retrograde (6F/0.018) access; -over-the-wire (OTW) -0.035'' compatible - diameter 4.00-7.00mm, in 1 mm increments - length: 40-60-80-120-150mm - compatible with 5-6-7F introducer - catheter length: 80 and 130cm (for all available balloon sizes) - catheter length: 40cm (for balloons of 40, 60, and 80 mm length) - nominal pressure: 8 atm; -ОТW technique - compatible with 0.035’’ wires - balloon diameter: 4.0-8.0mm - length: 20.0mm - 80.0 mm, or longer - compatible with 5-7F introducers - nominal pressure: 10bar+/-5%; - ОТW technique - hydrophilic coating - “dual lumen shaft“ - compatible with 0.035’’ wires - balloon diameter: 3.0-12.0mm - length: 20.0-300.0 mm - compatible with 5-7F introducers - catheter length: 80cm,130cm; - a balloon catheter made of material that provides both trackability and high-pressure within the same balloon - compatible with 5F (1.67 mm) introducers for balloons up to 7 mm, и 6F (2.00 mm) for balloons up to 10 mm - available in balloon lengths from 20mm to 200 mm, diameters from 3mm to 12 mm and catheter length of 75cm and 135 cm; - ablation active zone length: 7cm - catheter working length: 60-100cm - with depth markers - with a 0.025“ guide wire lumen; - with a nitinol guide wire with a platinum tip, with a diameter of 0.018 “and length 40cm+/-5% - introducer with: inner diameter of 2.9F, outer diameter from 4.0 to 5.0F, and length 7 cm ±5% - echogenic needle 21G, length 4 cm (+/-5%) and echogenic tip - “Check-flow“ valve; - catheter of 2.3-2.6F that can be inserted through 4F catheter with length from 65cm to 150cm - accepts guide wire with a diameter from 0.014“ to 0.018“ - platinum and iridium markers - with either a curved or straight tip; - length: 40-135cm - infusion length: 5-50cm - diameter: 4-5F - compatible with 0.035-0.038" guide wire; - with a double inner mesh and 3 radiopaque markers positioned at 4 and 6cm from the tip for precise lesion measurement and stent or balloon positioning - diameter: 4F - compatible with 0.035” wire - length: 150cm (+/-5%) - with straight or 30º curved tip; - OTW system (for OTW technique) - compatible with 0.018“ wire - balloon diameter: from 2-7 mm, or larger - balloon length: from 40-120 mm, or longer - guiding catheters length: 90-150cm - compatible with 4F and 5F; - with lesion entry profile of 0.020" (0.51 mm) - deflation time: 10 seconds - available in diameters from 2 to 8 mm - lengths from 40 to 200 mm and - shaft lengths of 90, 135 и 150 cm; - catheter length of 90, 130 и 170 cm - balloon diameter: 3 -12 mm - with various balloon lengths from 20 to 250mm - with two markers - compatible with 5F, 6F and 7F introducer; - made of Pebax semi-compliant balloon material with hydrophilic coating or equivalent - the tip is tapered, with a lesion entry profile not larger than 0.020” (0.51 mm) - deflation time: maximum 10 seconds - balloon diameter from 2.0 mm to 10.0 mm and length from 10 mm to 220mm - the catheter shall be available with shaft lengths from 90 cm to 150 cm - compatible with 5F introducer - suitable for broad clinical applications, including carotid and post-stent interventions; The set shall contain: - 5 cc vial with adhesive - 5F delivery catheter with a minimum length of 91cm - two laser markers for high echogenic visibility - 7F introducer with a minimum length of 80cm - 5F dilator with a minimum length of 87cm - applicator with an ergonomic pistol-shaped handle, allowing controlled release of 0.10cc adhesive during application - 0.035" guide wire with J-tip - two 3cc syringes; - catheter length: 90,150,200 cm - balloon diameter: 1.5 mm to 6.0 mm - balloon length: 20-240 mm - compatible with 4-6F introducer - with 2 radiopaque markers (20-150mm) and 4 (180-240mm) - NP 12atm; - catheter length: 75,135,200 cm - balloon diameter: 3 to 7.0 mm - balloon length: 20-240 mm - compatible with 5-7F introducer - with 2 radiopaque markers (20-150mm) and 4 (180-240mm) - NP 12atm; - with length up to 110 cm, straight tip - with an outer diameter of 6F - with an inner diameter of at least 2,21mm - PTFE inner lining - with Tuohy-Borst Sidearm valve and dilator with length of 122/102cm - compatible with 0.038” wire; - embolic protection filter with dimensions of 5 and 7.2mm and pores of at least 120 microns - the system includes a collection catheter - the entire system is compatible with 5F introducer or 6F guiding catheter; - RX (rapid exchange) - diameter range from 4.0 to 7.0mm - length from 15 to 40mm - shaft length: 80-135cm - compatible with 6F guiding catheter - RBP 14atm for all sizes; - the system shall provide rotational, frontal, and expandable cutting with blades rotating at approximately 70,000 rotations per minute - to have a minimum of five frontal blades for initial lesion engagement and treatment of stenotic or occluded vessels - to use an “up/down” blade technology to allow flexibility for treating multiple vessel diameters with a single catheter - to include active and continuous mechanical aspiration to remove thrombus and debris, reducing the risk of distal embolization and ensuring optimal debulking - the cutting mechanism shall be differential, selectively removing the diseased, non-elastic tissue from the healthy vascular tissue that needs to remain protected - the catheter shall contain internal lumens for infusion, aspiration, and guide wire navigation, as well as external ports for solution and aspiration - the catheter length shall be 120 cm, 135 cm or 145 cm, depending on configuration - all variants shall be compatible with 7 F introducer and 0.014” guide wire; - two embedded Platinum-iridium markers - compatible with 5-6F introducer - balloon diameter: 2-7mm - balloon length: 40,60,80,120,150mm - catheter length: 85 and 150cm for all available balloon sizes - max guide wire 0.018'' - inflation time of at least 30 secunds - Paclitaxel drug dose: 3.0 μg/mm2; - OTW system - compatible with 0.018'' wire - balloon diameter from 2-7mm - balloon length: 40-150mm - length of the guiding catheters: 135cm - compatible with 5F-7F introducers

Source officielle

Source : TED - Tenders Electronic Daily (Publications Office of the EU)

Vérifiez toujours les détails dans l'avis officiel.

Signaler une erreur dans cet avis

Dernière vérification auprès de TED - Tenders Electronic Daily (Publications Office of the EU) il y a 3 jours

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases - Ohrid

Macédoine du Nord

avis dans le registre
5
attribution
1
attribués au total
470 776 €

Attributions récentes

Contexte de marché

ouverts en ce moment, Équipements médicaux & produits pharmaceutiques
11 289
avis ouvert médian
141 435 €

Marchés similaires

Ouverts en ce moment

Déjà attribués

Ne manquez plus aucun marché comme celui-ci

34 nouveaux avis pour Équipements médicaux & produits pharmaceutiques en Macédoine du Nord au cours des 7 derniers jours. Recevez un e-mail quand de nouveaux avis paraissent. Gratuit.

Créer mon alerte

Raccourcis clavier

Parcourir une liste sans toucher la souris. Les raccourcis restent inactifs pendant la saisie dans un champ.

j
Résultat suivant
k
Résultat précédent
Entrée
Ouvrir le résultat
n
Page suivante
p
Page précédente
c
Comparer ce résultat
s
Ajouter ce résultat à la présélection
o
Ouvrir le résultat dans un nouvel onglet
x
Écarter ce résultat
/
Rechercher depuis n’importe quelle page
Ctrl K
Rechercher depuis n’importe quelle page
?
Afficher ces raccourcis
Échap
Fermer

Sommaire

Fermer
Se connecter

Langue