Skip to content
Aperlena

REQUEST FOR QUOTATION No 22 09 2026 NG - Next Generation Sequencing (NGS) of PCR amplicon samples

Open Contract notice

Key facts

Closes in
2 days
Where
Poland Małopolskie
CPV code The EU's common vocabulary for what is being bought: an eight-digit code every notice carries. Full entry
73110000 Research services
Original language
Polish
Source
via Baza Konkurencyjności Funduszy Europejskich (Ministerstwo Funduszy i Polityki Regionalnej), verified 4 days ago
Watch this tender

If the deadline moves or the notice is corrected, we email you. Log in

  1. Published
  2. Today
  3. Deadline open for 8 days
  4. Awarded pending

Summary

Machine-generated summary

The buyer seeks a service provider for next generation sequencing (NGS) of PCR amplicon samples, as part of the ONCO Prime project on personalised cancer therapy based on primary cell cultures from patients. The scope covers quality control of DNA verified by agarose gel electrophoresis with a separate report; PCR-free sequencing library preparation; library quality verification by qPCR and fragment length assessment; high-throughput sequencing on an SBS platform with patterned flow cells, producing PE150 reads at Q30 of at least 85%, with selectable output of 1.5 Gb, 15 Gb or 30 Gb per library; a summarising sequencing report; and bioinformatic data processing including quality control, filtering of low-quality reads, Q20 and Q30 reporting, error rate and GC content analyses, secure password-protected data transfer, online order monitoring and regular progress communication.

Description

Numer ogłoszenia: 2026-112-292611 Projekt: FENG.01.01-IP.02-0095/23 - "ONCO Prime: nowe możliwości personalizowanej terapii przeciwnowotworowej w oparciu o hodowlę komórek pierwotnych od pacjenta, charakteryzację omiczną i testy funkcjonalne" Część 1: NGS of PCR amplicon samples Sekwencjonowanie nowej generacji (NGS) próbek amplikonów PCR: kontrola jakości materiału DNA; czystość i integralność DNA muszą zostać zweryfikowane metodą elektroforezy w żelu agarozowym, a wyniki kontroli jakości powinny zostać przedstawione w odrębnym raporcie przed rozpoczęciem dalszego przetwarzania próbek; przygotowanie biblioteki sekwencyjnej bez etapu amplifikacji PCR (PCR-free); weryfikacja jakości biblioteki z wykorzystaniem ilościowej reakcji PCR (qPCR) oraz ocena rozkładu długości fragmentów; sekwencjonowanie przy użyciu wysokoprzepustowej platformy NGS opartej na technologii Sequencing by Synthesis (SBS) oraz technologii patternowanych komórek przepływowych (patterned flow cells), generującej odczyty sparowane o długości 150 pz (PE150) przy Q30 ≥ 85%, z możliwością wyboru wydajności sekwencjonowania wynoszącej 1,5 Gb, 15 Gb lub 30 Gb na bibliotekę, zgodnie z wymaganiami dla poszczególnych próbek; opracowanie raportu podsumowującego proces sekwencjonowania, zawierającego informacje o zastosowanej metodzie i przebiegu procesu, parametrach przebiegu sekwencjonowania oraz analizach statystycznych umożliwiających ocenę jakości sekwencjonowania i pokrycia próbek; bioinformatyczna obróbka danych obejmująca: kontrolę jakości wygenerowanych danych sekwencyjnych; filtrowanie odczytów niskiej jakości oraz odczytów zawierających sekwencje adapterowe; raportowanie parametrów Q20 i Q30; analizę rozkładu wskaźnika błędów; analizę rozkładu zawartości GC; bezpieczne przekazanie danych za pośrednictwem zabezpieczonej hasłem chmury obliczeniowej; dostęp do chronionego hasłem konta online umożliwiającego monitorowanie bieżącego statusu zamówienia; regularna komunikacja dotycząca postępu projektu i etapów przetwarzania próbek za pośrednictwem dedykowanego kierownika projektu; zapewnienie wsparcia technicznego i obsługi klienta przez cały okres obowiązywania umowy. Szacowany zakres umowy: przygotowanie bibliotek sekwencyjnych - minimum 10 bibliotek, maksimum 100 bibliotek; sekwencjonowanie - minimum 100 Gb, maksimum 1000 Gb (głębokość sekwencjonowania). Powyższe zakresy stanowią minimalny i maksymalny wolumen zamówień, które mogą zostać złożone przez Zamawiającego w ramach umowy. Zamawiający nie jest zobowiązany do wykorzystania maksymalnego wolumenu wskazanego powyżej, a Wykonawcy nie będą przysługiwać żadne roszczenia z tytułu złożenia zamówień o wartości lub wolumenie niższym niż maksymalny określony w umowie. *** Next Generation Sequencing (NGS) of PCR amplicon samples:  quality control of the DNA material; purity and integrity must be verified using agarose gel electrophoresis, with quality control results provided in a separate report prior to further sample processing;  preparation of a PCR-free sequencing library;  verification of library quality using quantitative PCR (qPCR) and subsequent assessment of fragment length distribution;  sequencing using a high-throughput next-generation sequencing platform based on Sequencing by Synthesis (SBS) technology and patterned flow cell technology, generating paired-end 150 bp reads (PE150) with Q30 ≥ 85%, with available sequencing output options of 1.5 Gb, 15 Gb, or 30 Gb per library, selectable according to the requirements of each sample;  generation of a report summarizing the sequencing process, including information on the sequencing method and workflow, sequencing run parameters, and statistical analyses enabling assessment of sequencing quality and sample coverage;  bioinformatic data processing including: o quality control of generated sequencing data; o filtering of low-quality reads and reads containing adapter sequences; o reporting of Q20 and Q30 metrics; o error rate distribution analysis; o GC content distribution analysis;  secure, password-protected delivery of data via cloud-based storage;  access to a password-protected online account enabling tracking of current order status;  regular communication regarding project progress and sample processing stages through a dedicated project manager;  provision of technical support and customer care throughout the contract period. Estimated scope of the contract: library preparation - minimum 10 libraries, maximum 100 libraries; sequencing - minimum 100 Gb, maximum 1000 Gb (sequencing depth). The above ranges constitute the minimum and maximum volume of orders that may be placed by the Ordering Party under the contract; the Contractor shall have no claim in respect of orders below the maximum volume. CPV: 73110000-6 Usługi badawcze Miejsce realizacji: Kraków (małopolskie) Źródło: Ministerstwo Funduszy i Polityki Regionalnej, Baza Konkurencyjności Funduszy Europejskich; pobrano 2026-09-22; dane przetworzone.

Can I bid?

Official source

Source: Baza Konkurencyjności Funduszy Europejskich (Ministerstwo Funduszy i Polityki Regionalnej)

Always verify details on the official notice.

Last verified against Baza Konkurencyjności Funduszy Europejskich (Ministerstwo Funduszy i Polityki Regionalnej) 4 days ago

Documents on Baza Konkurencyjności Funduszy Europejskich (Ministerstwo Funduszy i Polityki Regionalnej) (Polish)

More from this buyer

Full buyer profile

2 open tenders right now

This buyer has no award history in this sector yet. Usual winners, Research & development - Poland

Company Wins Total awarded Last win
EVALU Sp. z o.o. 5 €87,037 Aug 2026
IBC Advisory S.A. 4 €120,798 Jul 2026
STREFA PRZYRODY Kamil Martyniak 4 €38,696 Jun 2026
Pracownia Badań i Analiz Przyrodniczych Dariusz Płąchocki 3 €57,396 May 2026
Openfield Sp. z o.o. 3 €38,980 Aug 2026

Based on 208 awards with a linked company profile over the last 2 years.

Similar tenders

Market context

Avg. open tender · Research & development
€3,208,156
536 open across Europe right now
Buyer track record on Aperlena
16 notices tracked · 0 awarded

Never miss a tender like this

36 new notices in Research & development in Poland in the last 7 days. Get an email when new ones appear. Free.

Set up my alert

2 days left

Open notice

Keyboard shortcuts

Read a list without reaching for the mouse. The shortcuts stay quiet while you type in a field.

j
Next result
k
Previous result
Enter
Open the result
n
Next page
p
Previous page
c
Compare this result
s
Shortlist this result
/
Search from any page
Ctrl K
Search from any page
?
Show these shortcuts
Esc
Close