Zum Inhalt springen
Aperlena

Rental Agreement for a high sensitivity Tandem Mass Spectrometer - High Performance Liquid Chromatography system for analysis of hormones biological fluids.

Vergeben Vergabebekanntmachung Keine Frist veröffentlicht
Ausschreibung beobachten

Die Angebotsfrist ist vorbei. Ein Zuschlag oder eine Berichtigung zu dieser Bekanntmachung: eine E-Mail, wenn das Register es sieht. Anmelden

  1. Veröffentlicht
  2. Vergeben ausstehend

Beschreibung

The CUH Blood Sciences Biochemical Genetics Unit is looking to replace a high sensitivity Triple Quadrupole Tandem Mass Spectrometer (TMS) coupled to an ultra-high pressure liquid chromatography (HPLC) system. This system runs 10 methods including newborn blood spot analysis that were developed either in-house or in conjunction with suppliers. The Blood Sciences labs currently have four Sciex triple quadrupole tandem mass spectrometers (TMS) linked to Shimadzu or Sciex (Exion) liquid chromatography (HPLC) systems. This includes the system that we are replacing. The combined laboratories currently process around 120,000 samples a year through the four LC-Tandem Mass Spectrometer systems. Results generated from the systems are from technically/clinically validated methods and are used for diagnosis of endocrine and metabolic disorders, as well as for neonatal screening tests. The replacement system must be capable of quantitation of a range of metabolites in human serum, urine and blood spot and therefore must be capable of using Chemoview to quantitate the newborn screening blood spot assays. Some of the analytes are at nmol/L concentrations in human serum e.g. urine matanepherine, so a high sensitivity system is essential. The TMS - HPLC system must have the following critical elements: TMS - The TMS must have multiple modes of operation including multiple reaction monitoring and scan modes. Scan modes must include precursor ion scan, product ion scan, neutral loss scan. - The TMS must be capable of Atmospheric Pressure Chemical Ionisation (APCI) and electrospray (ESI) ionisation modes with proven use of APCI for clinical hormone analyses. - The TMS must be capable of positive and negative modes. - The TMS must be capable of polarity switching within a sample acquisition run with a minimum settling time of 5msec between polarities. - The TMS must accept a fluid flow rate from 5µL/min to 3000µL/min, without flow splitting. - To allow for future development needs the TMS must have an option to be upgraded to a linear ion trap system that will provide additional scan modes such as MRM3, Enhanced Product Ion Scan. - The TMS must have an integral infusion pump under full control of the system software to allow infusion rates up to 30µL/min to allow compound tuning and for ion suppression testing. - The TMS control software must be compatible with multi-vendor HPLC systems e.g. Shimadzu, Agilent, Waters. - The system must be capable of the self-generation of all gases required for routine use (i.e. no requirement for a gas cylinder in the lab). - A suitable roughing pump must be supplied. This must be an oil-free pump. - Results must be able to be exported in .txt format to allow uploading to our current hospital information system. - Current methods in use in the Biochemical Genetics Unit must be directly transferrable without the need for re-development. HPLC - The HPLC system must have the ability of a dual binary pump arrangement allowing pressures up to 10,000PSI. This setup is to allow online solid phase extraction using 2-position valves. - There must be a minimum of 4 solvent lines per pump with inline degassers. If binary pumps are proposed, there must be 4 solvent lines for each side of the binary pump. The LC must have the ability to switch to different solvent input lines, analytical columns without operator intervention to allow running of multiple assays to be processed consecutively. - The HPLC autosampler must be capable of injecting from 1 to 50µL. - The HPLC autosampler must have at least six positions for plate/vials and must be able to inject from 96 shallow well plates, 96 deep well plates and vials. It must be capable of using these in combination without changing hardware configuration. - The column oven must have an operating temperature range of 5 to 85°C. - The column oven and must be able to accommodate six analytical columns of 25cm length. - The column oven must be able to accommodate and drive 2, 7-port 6-position valves to allow switching between columns and therefore multiplexing of analytical methods. - The system must be able to drive 3 2-position 6-port valves independently to allow sequential running of different methods.

Amtliche Quelle

Quelle: Find a Tender Service (UK Cabinet Office / Crown Commercial Service)

Prüfen Sie alle Angaben stets in der amtlichen Bekanntmachung.

Zuletzt mit Find a Tender Service (UK Cabinet Office / Crown Commercial Service) abgeglichen vor 1 Monat

Unterlagen auf Find a Tender Service (UK Cabinet Office / Crown Commercial Service) (Englisch)

Mehr von diesem Auftraggeber

Vollständiges Auftraggeberprofil

Jüngste Vergaben

Änderungsverlauf

Jedes Mal, wenn eine offizielle Quelle diese Bekanntmachung mit geändertem Inhalt erneut veröffentlicht hat. Wir beobachten alle Quellen, die wir indexieren, auch regionale Kopien derselben Bekanntmachung.

  1. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am -
    • Leistung und Kriterien: Die Beschreibung wurde erweitert. Vor dem Angebot erneut lesen.
  2. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am 20. Juli 2026
    • Leistung und Kriterien: Die Beschreibung wurde gekürzt. Vor dem Angebot erneut lesen.
  3. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am -
    • Leistung und Kriterien: Die Beschreibung wurde erweitert. Vor dem Angebot erneut lesen.
  4. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am 20. Juli 2026
    • Leistung und Kriterien: Die Beschreibung wurde gekürzt. Vor dem Angebot erneut lesen.
  5. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am -
    • Leistung und Kriterien: Die Beschreibung wurde erweitert. Vor dem Angebot erneut lesen.
  6. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am 20. Juli 2026
    • Leistung und Kriterien: Die Beschreibung wurde gekürzt. Vor dem Angebot erneut lesen.
  7. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am -
    • Leistung und Kriterien: Die Beschreibung wurde erweitert. Vor dem Angebot erneut lesen.
  8. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am 20. Juli 2026
    • Leistung und Kriterien: Die Beschreibung wurde gekürzt. Vor dem Angebot erneut lesen.
  9. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am -
    • Leistung und Kriterien: Die Beschreibung wurde erweitert. Vor dem Angebot erneut lesen.
  10. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am 20. Juli 2026
    • Leistung und Kriterien: Die Beschreibung wurde gekürzt. Vor dem Angebot erneut lesen.
  11. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am -
    • Leistung und Kriterien: Die Beschreibung wurde erweitert. Vor dem Angebot erneut lesen.
  12. Vor dem Angebot lesen
    • Zuschlagsdatum: Zuschlag am 20. Juli 2026
    • Leistung und Kriterien: Die Beschreibung wurde gekürzt. Vor dem Angebot erneut lesen.

Folgen Sie dieser Ausschreibung, und wir mailen Ihnen jede Änderung sofort. Konto erstellen

Ähnliche Ausschreibungen

Marktkontext

Vergabehistorie auf Aperlena
95 erfasste Bekanntmachungen · 94 vergeben

Verpassen Sie keine Ausschreibung wie diese

6.844 neue Bekanntmachungen für alle Sektoren in Vereinigtes Königreich in den letzten 7 Tagen. Erhalten Sie eine E-Mail, wenn neue erscheinen. Kostenlos.

Benachrichtigung einrichten

Tastaturkürzel

Eine Liste lesen, ohne zur Maus zu greifen. In einem Eingabefeld bleiben die Kürzel stumm.

j
Nächstes Ergebnis
k
Vorheriges Ergebnis
Enter
Ergebnis öffnen
n
Nächste Seite
p
Vorherige Seite
c
Dieses Ergebnis vergleichen
s
Dieses Ergebnis auf die Merkliste setzen
/
Zum Suchfeld springen
?
Diese Kürzel anzeigen
Esc
Schließen