Zum Inhalt springen
Aperlena

Norway - Laboratory, optical and precision equipments (excl. glasses) - Equipment for weekend sequencing for the Department of Medical Genetics at UNN HF Tromsø.

Vergeben Vergabebekanntmachung Keine Frist veröffentlicht
Ausschreibung beobachten

Die Angebotsfrist ist vorbei. Ein Zuschlag oder eine Berichtigung zu dieser Bekanntmachung: eine E-Mail, wenn das Register es sieht. Anmelden

  1. Veröffentlicht
  2. Vergeben ausstehend

Beschreibung

The Medical Genetics Department at the University Hospital of North Norway (UNN) shall procure a sequentialator from PacBio to read long fragments of DNA and RNA sequencing (long-read sequencing, LRS). The instruments shall be used for diagnostics and shall replace and supplement the current diagnostics based on short-read sequencing (SRS). This is because LRS detects some types of genetic variation better than SRS, e.g. major structural deviations and methylation status. Method transfer shall therefore be carried out from the current SRS to a new LRS for selected medical indications and it is therefore very important that these sequentators deliver a sequence of very high quality and reproducibility. Of the above mentioned reasons, PacBio, as far as the contracting authority is aware of, is the only supplier who can fulfil the requirements. The terms in PPR § 13-4 (b) no. 2 are considered fulfilled. The Medical Genetics Department at the University Hospital of North Norway (UNN) intends to procure 1 sequentialator from PacBio to read long fragments of long-read sequencing (DNA and RNA sequencing). The instruments shall be used for diagnostics and shall replace and supplement the current diagnostics based on short-read sequencing (SRS). This is because LRS detects some types of genetic variation better than SRS, e.g. major structural deviations and methylation status. Method transfer shall therefore be carried out from the current SRS to a new LRS for selected medical indications and it is therefore very important that these sequentators deliver a sequence of very high quality and reproducibility. There are several technical specifications that are decisive for achieving the quality we need for this purpose, for example: - The sequencing must be able to carry out sequencing with long read lengths of DNA and RNA for clinical samples. The read length of sequential fragments must at least be median 10-15 kb. At least 90% of the bases must have a quality of Q30 or higher in a typical 30X human genome. The instrument shall be particularly suitable for detecting major structural deviations and methylation status. - The data quality of SNP variants and short parts <50 bp must be at least as good as that achieved by Illumina SRS. This is important so that the analytical sensitivity of the analysis offer is not reduced for these types of variants and that the quality of the analysis offer is not, therefore, impaired for the patient analyses that shall only be carried out on a new long-read sequentator. - Sensitivity and precision must be documented in a reference dataset for the entire genome (i.e. not just the encoded areas in the genome) with the following parameters met: (i) F1 score > 99 % for SNS. (ii) F1 score > 95 % for INDEL's. (iii) F1 score >90 % for structural variants (SV's). (iv) Recall or F1-score for SNVs and INDEL are for technically challenging medical relevant genes (CMRG, as defined in Wagner et al., Nature Biotechnology 2022: https://www.nature.com/articles/s41587-021-01158-1) at least on par with Illumina SRS. High F1 scores (low false positive and negative variant detection) are decisive in avoiding extremely time-consuming and resource-demanding downstream verification of variants/missing cause variants. - Variantcalling to the mentioned standards must be achieved with an average 30X sequencing depth. This is required to avoid the need for deeper sequencing, including duotone readings, in order to achieve the necessary data quality. The need for deeper sequencing will increase the costs and time consumption, which is not acceptable. - Sequence data cannot have systematic bias in basecalling and variant calculation, including in homopolymer areas. Of the above mentioned reasons, PacBio, as far as the contracting authority is aware of, is the only supplier who can fulfil the requirements. The terms in PPR § 13-4 (b) no. 2 are considered fulfilled.

Amtliche Quelle

Quelle: TED - Tenders Electronic Daily (Publications Office of the EU)

Prüfen Sie alle Angaben stets in der amtlichen Bekanntmachung.

Zuletzt mit TED - Tenders Electronic Daily (Publications Office of the EU) abgeglichen vor 1 Monat

Mehr von diesem Auftraggeber

Vollständiges Auftraggeberprofil

85 offene Ausschreibungen derzeit

Jüngste Vergaben

Änderungsverlauf

Jedes Mal, wenn eine offizielle Quelle diese Bekanntmachung mit geändertem Inhalt erneut veröffentlicht hat. Wir beobachten alle Quellen, die wir indexieren, auch regionale Kopien derselben Bekanntmachung.

  1. Vor dem Angebot lesen
    • Leistung und Kriterien: Die Beschreibung wurde erweitert. Vor dem Angebot erneut lesen.

Folgen Sie dieser Ausschreibung, und wir mailen Ihnen jede Änderung sofort. Konto erstellen

Ähnliche Ausschreibungen

Marktkontext

Ø offene Ausschreibung · Labor- & Präzisionsgeräte
5.436.762 €
2.032 aktuell offen in Europa
Vergabehistorie auf Aperlena
775 erfasste Bekanntmachungen · 161 vergeben
170.986.269 € vergebenes Volumen

Verpassen Sie keine Ausschreibung wie diese

11 neue Bekanntmachungen für Labor- & Präzisionsgeräte in Norwegen in den letzten 7 Tagen. Erhalten Sie eine E-Mail, wenn neue erscheinen. Kostenlos.

Benachrichtigung einrichten

Tastaturkürzel

Eine Liste lesen, ohne zur Maus zu greifen. In einem Eingabefeld bleiben die Kürzel stumm.

j
Nächstes Ergebnis
k
Vorheriges Ergebnis
Enter
Ergebnis öffnen
n
Nächste Seite
p
Vorherige Seite
c
Dieses Ergebnis vergleichen
s
Dieses Ergebnis auf die Merkliste setzen
/
Zum Suchfeld springen
?
Diese Kürzel anzeigen
Esc
Schließen