Przejdź do treści
Aperlena

Danmark - Laboratorieudstyr, optisk udstyr og præcisionsudstyr (ikke briller) - Microscope for 2-photon multiscale imaging

Udzielony Ogłoszenie o udzieleniu zamówienia Nie opublikowano terminu
Obserwuj ten przetarg

Składanie ofert zakończone. Udzielenie zamówienia lub sprostowanie tego ogłoszenia: e-mail, gdy rejestr to zobaczy. Zaloguj się

  1. Opublikowano
  2. Udzielony oczekuje

Opis

The contract concerns the procurement of an advanced inverted two-photon microscope for in vivo multiscale imaging of biological tissues. The system will support research activities at the Department of Biomedicine, including high-speed calcium imaging, fluorescence lifetime imaging (FLIM), tracking of cellular processes, and deep-tissue imaging in living animal models. The system must also integrate seamlessly with existing microscopy platforms within the department's core facility. Necessity of the Technical Requirements The department's existing two-photon microscope no longer meets current research requirements. The new system must provide high-speed simultaneous acquisition of at least two to three imaging channels, freely adjustable spectral detection on non-descanned detectors (NDD) for optimal fluorophore separation, resonant scanning technology for imaging rapid physiological processes in living tissues, FLIM functionality and advanced automated imaging workflows, high-resolution with large field of view deep-tissue imaging capabilities and full compatibility with existing Leica software and equipment already used in the core facility, thereby ensuring efficient workflows, minimizing user training requirements, and facilitating data analysis. These capabilities are necessary to support the research activities funded through the awarded infrastructure grant and to serve the needs of approximately 200 active users of the facility. Based on the market analysis, it has therefore been concluded that only Leica Microsystems is capable of delivering a system that satisfies the contracting authority's minimum technical requirements. Consequently, the contract is awarded without prior publication of a contract notice due to the absence of competition for technical reasons. Market analysis A market assessment was conducted covering the principal suppliers of inverted two-photon microscopy systems. The assessment demonstrated that while several suppliers could meet certain individual requirements, only the Leica STELLARIS 8 DIVE meets all minimum technical requirements. Specifically, the Leica system is the only solution that combines resonant scanning at the speed required for the intended in vivo applications, freely adjustable spectral detection on non-descanned detectors, real-time optimisation of detector performance during imaging and full integration with existing Leica platforms and analysis software already deployed in the core facility. It has therefore been concluded that only Leica Microsystems purchased from Triolab AS, can deliver a system that satisfies the contracting authority's minimum technical requirements. Consequently, the contract is awarded without prior publication of a contract notice due to the absence of competition for technical reasons.

Oficjalne źródło

Źródło: TED - Tenders Electronic Daily (Publications Office of the EU)

Zawsze weryfikuj szczegóły w oficjalnym ogłoszeniu.

Ostatnia weryfikacja w TED - Tenders Electronic Daily (Publications Office of the EU) 1 miesiąc temu

Więcej od tego zamawiającego

Pełny profil zamawiającego

7 otwartych przetargów w tej chwili

Ostatnie udzielenia

Podobne przetargi

Kontekst rynkowy

Śr. otwarty przetarg · Sprzęt laboratoryjny i precyzyjny
5 515 565 €
1 972 otwartych teraz w Europie
Historia zamawiającego w Aperlena
64 zarejestrowanych ogłoszeń · 50 udzielonych
126 155 479 € w udzielonych zamówieniach

Nie przegap przetargów takich jak ten

9 nowych ogłoszeń w ostatnich 7 dniach: Sprzęt laboratoryjny i precyzyjny, Dania. Otrzymuj e-mail, gdy pojawią się nowe ogłoszenia. Za darmo.

Ustaw mój alert

Skróty klawiszowe

Przeglądaj listę bez sięgania po mysz. Skróty nie działają podczas pisania w polu.

j
Następny wynik
k
Poprzedni wynik
Enter
Otwórz wynik
n
Następna strona
p
Poprzednia strona
c
Porównaj ten wynik
s
Dodaj ten wynik do krótkiej listy
/
Przejdź do pola wyszukiwania
?
Pokaż te skróty
Esc
Zamknij