Fire Compartmentation Works - Town Hall & Watermark

Clôturé Modification
Suivre ce marché

Les offres sont closes. Une attribution ou un rectificatif sur cet avis : un e-mail quand le registre le voit. Se connecter

  1. Publié
  2. Date limite ouvert 12 jours
  3. Attribué en attente

Description

Fire Compartmentation Works - Ivybridge Town Hall & The Watermark, Devon 1. Project Overview You are invited to submit a tender for compartmentation and associated fire safety works at the project premises. The works shall be undertaken in a live office environment, and contractors must plan accordingly to minimise disruption while maintaining safety and escape routes at all times. Tender pricing shall be based on the information and drawings provided. The successful contractor will be required to attend site to verify the estimated works prior to final commitment. 2. Scope of Works This section forms an integral part of the Invitation to Tender and sets out the specification. 2.1 General Compartmentation Works • Installation and/or reinstatement of fire compartmentation in accordance with supplied drawings • All works to achieve minimum 30-minute fire resistance • All penetrations to be appropriately fire-stopped using tested and certified systems • Compliance with current UK fire safety regulations and best practice 2.2 Ground Floor Works • Ground floor compartmentation to follow compartment lines shown on drawings • Fire stopping and sealing to all service penetrations • Associated making good 2.3 First Floor Works • Replacement of false ceilings within areas shown on drawings • Preferred solution: o Fire-rated ceiling tiles o Fire-rated suspended grid system • Rectification of one small electrical cupboard ceiling • All ceiling installations to maintain required fire resistance 2.4 Fire Door Remedial Works (Town Hall & The Watermark) • All fire door works remedial works • Works to follow recommendations outlined in their individual Fire Door Survey Reports • Includes but not limited to: o Intumescent strips o Smoke seals o Door closers o Thresholds o Adjustments to gaps o Certification where applicable 2.5 Secondary Escape Stairway - Area 3 • Area (3) secondary escape stairway requires scaffolding access • The stairway must remain fully operational as an escape route at all times • Contractor must: o Provide safe temporary protection o Maintain minimum escape width o Provide on-site management during works o Coordinate phasing to ensure continuous compliance 3. Electrical Fixture Reinstatement (Point Pricing Required) Tenderers must provide separate point pricing for: • Removal and reinstatement of existing ceiling lights (Qty: 10) • Removal and reinstatement of smoke detectors (Qty: 10) • All fittings to be reinstated with: o Fire rated fire hood covers o Appropriate fire sealing

Source officielle

Source : Find a Tender Service (UK Cabinet Office / Crown Commercial Service)

Vérifiez toujours les détails dans l'avis officiel.

Dernière vérification auprès de Find a Tender Service (UK Cabinet Office / Crown Commercial Service) il y a 1 mois

Documents sur Find a Tender Service (UK Cabinet Office / Crown Commercial Service) (anglais)

Marchés similaires

2

jours restants

Supply & Fit of Timber Fencing

Royaume-Uni Travaux de construction Newcastle City Council

9 344 921 €

2

jours restants

Building 260 Refurbishment BATSUB

Royaume-Uni Travaux de construction Defence Infrastructure Organisation

526 420 €

3

jours restants

Estates Improvement Framework

Royaume-Uni Travaux de construction The Police and Crime Commissioner for Humberside

11 659 768 €

Contexte de marché

Appel ouvert moyen · Travaux de construction
32 045 971 €
30 248 ouverts en Europe actuellement
Historique de l'acheteur sur Aperlena
1 avis suivis · 0 attribués

Ne manquez plus aucun marché comme celui-ci

163 nouveaux avis pour Travaux de construction en Royaume-Uni au cours des 7 derniers jours. Recevez un e-mail quand de nouveaux avis paraissent. Gratuit.

Créer mon alerte

Raccourcis clavier

Parcourir une liste sans toucher la souris. Les raccourcis restent inactifs pendant la saisie dans un champ.

j
Résultat suivant
k
Résultat précédent
Entrée
Ouvrir le résultat
n
Page suivante
p
Page précédente
c
Comparer ce résultat
s
Ajouter ce résultat à la présélection
/
Aller au champ de recherche
?
Afficher ces raccourcis
Échap
Fermer