Aller au contenu
Aperlena

Deutschland - Laser - Photocathode Laser System

Attribué Avis d'attribution Aucune date limite publiée
Suivre ce marché

Les offres sont closes. Une attribution ou un rectificatif sur cet avis : un e-mail quand le registre le voit. Se connecter

  1. Publié
  2. Attribué en attente

Description

Delivery, installation and commissioning of a Photocathode Laser System Helmholtz-Zentrum Dresden-Rossendorf (HZDR) has been working on the development of a superconducting electron source (SRF gun) for about 20 years. An integral part of this electron source is a photocathode laser which, in combination with a photocathode, uses the external photoelectric effect to generate electron pulses. These pulses are then accelerated by the electric field of the superconducting RF resonator. The required laser wavelength for this purpose is about 260 nm, while the aimed pulse energy at this wavelength is 5 μJ. Detailed requirements in the table below (2. Performance quote) are specified separately for the fundamental wavelength in infrared (IR) and the 4th harmonic in ultraviolet (UV). Pulse repetition rate shall be flexible and reach 2 MHz. The average power in UV has to reach at least 1 W. Laser pulse duration is a key optimization parameter that needs to be variable in the range of 0.3-10 ps FWHM. Moreover, the temporal (longitudinal) profile of the laser pulse overall is important for properties of the generated electron pulse and thus also needs to be adjustable. For this, a spatial light modulator for modifying the spectrum needs to be integrated in the offered system. It is desirable that the manufacturer finds settings of the spectral shaper that result in a flat-top temporal shape of the UV pulse. Given that the temporal shape of a chirped pulse is critical in the planned application, spectral smoothness, stability and absence of long wings or shoulders are of high importance. Spectrum distortions caused by nonlinear effects shall be insignificant even at the maximum required pulse energy. Ability to synchronize the oscillators' repetition rate to a radio-frequency (RF) reference signal is necessary. Achievable integrated time jitter in the range between 10 Hz and 1 MHz of the laser with respect to the reference shall not exceed 100 fs. However, synchronization electronics are not part of the current tender and will be obtained from another source. The oscillator needs to be prepared for repetition rate locking, i.e. contain a short-range and a long-range actuators for fine adjustment of the cavity length. Another aspect of synchronization is the ability to control the repetition rate and the emission time of the laser by an external trigger signal. This ability needs to be available. Reliability and permanent availability (24/7) are of particular importance. The system will be located in an optical laboratory with ±1°C temperature stability. Beside the fulfilment of the criteria described in annex 01A, the scope of deliveries and services includes, that means are to be offered in the quotation: • Factory Acceptance Test (FAT), with proof of fulfilment of the performance requirements • Delivery according to DDP (Incoterms 2010) to the place of usage • Installation und commissioning including On-Site Acceptance Test (OSAT), with proof of fulfilment of the performance requirements • 12 months warranty from OSAT • CE marking • complete manual in English • suitable "water-to-water chiller"

Source officielle

Source : TED - Tenders Electronic Daily (Publications Office of the EU)

Vérifiez toujours les détails dans l'avis officiel.

Dernière vérification auprès de TED - Tenders Electronic Daily (Publications Office of the EU) il y a 1 mois

Plus de cet acheteur

Profil complet de l'acheteur

8 marchés ouverts actuellement

Attributions récentes

Historique des modifications

Chaque republication de cet avis par une source officielle avec un contenu différent. Nous surveillons toutes les sources que nous indexons, y compris les copies régionales du même avis.

  1. A lire avant de repondre
    • Intitule: "Deutschland - Laser - Photocathode Laser System" vers "Deutschland – Laser – Photocathode Laser System"
    • Objet et critères: La description a été étoffée. À relire avant de repondre.

Suivez ce marche et nous vous ecrivons dès qu'il change. Créer un compte

Marchés similaires

2

jours restants

Säurelagerungsstand

Allemagne Équipements de laboratoire & de précision Bundesanstalt für Materialforschung und -prüfung (BAM)

2

jours restants

Laminar Air Flow Cabinet

Allemagne Équipements de laboratoire & de précision Universitätsklinikum Magdeburg A.ö.R

Contexte de marché

Appel ouvert moyen · Équipements de laboratoire & de précision
5 729 702 €
2 164 ouverts en Europe actuellement
Historique de l'acheteur sur Aperlena
40 avis suivis · 14 attribués
800 000 € de contrats attribués

Ne manquez plus aucun marché comme celui-ci

65 nouveaux avis pour Équipements de laboratoire & de précision en Allemagne au cours des 7 derniers jours. Recevez un e-mail quand de nouveaux avis paraissent. Gratuit.

Créer mon alerte

Raccourcis clavier

Parcourir une liste sans toucher la souris. Les raccourcis restent inactifs pendant la saisie dans un champ.

j
Résultat suivant
k
Résultat précédent
Entrée
Ouvrir le résultat
n
Page suivante
p
Page précédente
c
Comparer ce résultat
s
Ajouter ce résultat à la présélection
/
Aller au champ de recherche
?
Afficher ces raccourcis
Échap
Fermer